Skip to content
StandbyWise

Tool

Battery & Maintenance Kit Finder

Pick your Generac series and model size. Guardian and Next Generation generators use different batteries, engines, and maintenance kits, so this finder keeps the two series strictly separate and only shows specs we verified against a Generac source — with the citation attached. Where a kit or part number is not verified for a model, it says so instead of guessing.

The series matters: Guardian and Next Generation use different batteries, engines, and maintenance kits. Check your generator's nameplate or manual if you are unsure.

Engine in Generac's data for this size: 999cc, 2 cylinder

Battery — Guardian Series

Required: 12 volts, Group 26R, 540 CCA minimum — wet cell (battery not included with the generator).

Alternative per Generac: 12 volts, Group 35 AGM, 650 CCA minimum (maintenance-free style; Generac support describes the 35AGM as an alternative recommendation to the standard 26R)

Generac battery part: G005819-0 — '26R Wet Cell Battery', described by Generac as the recommended 26R wet cell battery for use with all air-cooled standby products (listed in the 20/22/24 kW spec sheet accessories)

Generac support: '26R Wet Cell Battery — This battery is used by Guardian series and older generator models.' Battery requirement is stated identically on the Guardian 10/14/18, 20/22/24, and 26 kW spec sheets and on the 18kW and 22kW product pages.

Not interchangeable between series. Guardian and Next Generation use DIFFERENT batteries: Guardian = 12V Group 26R wet cell, 540 CCA minimum (or Group 35 AGM, 650 CCA minimum). Next Generation = 12V AGM PowerSports Group BTX30L / Group Size 30L, 400 CCA minimum. A 26R does NOT satisfy the Next Generation requirement per Generac spec sheets, and the 30L AGM does not appear in any Guardian requirement found. Do not flatten these.

Sources

Maintenance kit — Guardian Series 22 kW

Generac kit 6485 (G006485-0) — Scheduled Maintenance Kit. Oil is not included in the kit.

Contents (Generac's 2013 kit bulletin 0198110SBY-C)

  • Air filter
  • Oil filter
  • Spark plugs — 2
  • Oil funnel
  • Chamois
  • Reminder sticker

The bulletin notes contents of kits may vary and that its kit list covers 2013 models — confirm contents against the current kit listing before relying on this list.

  • Listed by Generac as a Scheduled Maintenance Kit accessory (G006485-0) in the Guardian 20/22/24 kW spec sheet: 'Scheduled maintenance kits provide all the items necessary to perform complete routine maintenance on a [Generac] automatic standby generator (oil not included).'
  • Generac's 2013 air-cooled maintenance-kit bulletin (0198110SBY-C) Kit Contents table for kit 006485-0: Air Filter — included; Oil Filter — included; Spark Plug(s) — 2; Oil Funnel — included; Chamois — included; Reminder Sticker — included. Bulletin note: 'Contents of kits may vary'; the kits listed in that bulletin are for 2013 models.
  • The same bulletin states maintenance is recommended at every 200 hours or 2 years, and that oil is purchased separately.

The Generac documents read in this pass place G006485-0 with the 999cc Guardian 20/22/24 kW family (it is the maintenance-kit accessory on that family's spec sheet, which covers models 7042/7043 22 kW and 7209 24 kW). A detailed model-by-model fit list, any 16 kW / EcoGen fit, and any 26 kW fit were NOT stated in a manufacturer source read in this pass — dealer/retailer listings claim them, but they are not recorded here as verified.

Sources

Individual parts & oil — Guardian Series 22 kW

Oil filter
070185ES — the filter Generac's oil-capacity data lists for both the Guardian and Next Generation series.
Oil capacity (with filter)
Approx. 1.9 qt (1.8 L) — 999cc, 2 cylinder engine.
Air filter (Guardian 22 kW only)
0J8478S — from Generac's 22 kW (G0070420) product specifications.
Spark plug (Guardian 22 kW only)
0G0767A — from Generac's 22 kW (G0070420) product specifications.
Engine oil
After the initial 25-hour break-in oil change: Generac proprietary full synthetic 5W-20 Gaseous Engine Oil (GEO), full operating temperature range, for all home standby generators. Factory fill is 5W-30 conventional (organic) oil — break-in only; do not switch to synthetic until after the initial 25-hour oil change. We do not publish spark plug gap figures — no Generac source in our verified data states them yet.

Sources

22 kW parts source

Safety note: StandbyWise provides lookup, sizing, parts, and cost information only. It does not provide instructions for gas-line work, transfer-switch wiring, or internal generator repair. See our disclaimer.